Products

Land Power

Special Battery for Russian design tanks and armoured vehicles


Applications

  • Armoured Vehicles: BMP-1, BMP-2, BMP-3, SAU-122-GVOZDIKA, SAU-152-AKACIA, ZRK-OSA, MT-LB, MT-LB-V, MT-LB-VM, MT-LB-U, T-LB-SE, BTR, Engineering vehicles
  • Tanks: T-55A, T-55AM2, T-64, T-72, T-80, T-90, T-84
 
 
Battery type Voltage Nominal capacity C20 at 25°C Dimensions Lmax/B/H, mm Weight w/ electrolyte, kg

MBL 6 ST 140 PK

12 V

140

570/243/238

51



Operational temperature: From -50°C to 70°C
Reserve capacity: 270 min

Cranking current: 420 A

  • requirements at 25°C: 330 sec. to Uend = 9 V
  • requirements at -30°C: 90 sec. to Uend = 6 V
 
Life duration:
  • Motto hours: 1 000
  • Vehicle race: 50 000 km
  • Service life: 3 years
  • Storage (dry charged): 3 years


- Longtime shocks, acceleration 15g, impulse duration from 10 to 15 msec, frequency 70 to 100 shocks per minute. Quantity shocks: 2000.

- One shock, acceleration 150g, impulse duration from 1 to 5 msec, frequency 1 to 2 shocks per minute. Quantity shocks: 3 in each direction.

 
 
Battery type Voltage Nominal capacity C20 at 25°C Dimensions Lmax/B/H, mm Weight w/ electrolyte, kg

MBL 6 ST 160 PK

12 V

160

570/243/238

54



Operational temperature: From -50°C to 70°C
Reserve capacity: 290 min

Cranking current: 480 A

  • requirements at 25°C: 330 sec. to Uend = 9 V
  • requirements at -30°C: 90 sec. to Uend = 6 V

Life duration:

  • Motto hours: 1 000
  • Vehicle race: 50 000 km
  • Service life: 3 years
  • Storage (dry charged): 3 years


- Longtime shocks, acceleration 15g, impulse duration from 10 to 15 msec, frequency 70 to 100 shocks per minute. Quantity shocks: 2000.

- One shock, acceleration 150g, impulse duration from 1 to 5 msec, frequency 1 to 2 shocks per minute. Quantity shocks: 3 in each direction.

 
 
Battery type Voltage Nominal capacity C20 at 25°C Dimensions Lmax/B/H, mm Weight w/ electrolyte, kg

MBL 12 ST 75 PK

24 V

75

586/243/240

62



Operational temperature: From -50°C to 70°C

Reserve capacity: 123 min

Cranking current: 400 A

  • requirements at 25°C: 180 sec. to Uend = 18 V
  • requirements at -30°C: 0 sec. to Uend = 12 V


Life duration:

  • Motto hours: 1 000
  • Vehicle race: 50 000 km
  • Service life: 3 years
  • Storage (dry charged): 3 years
 
- Longtime shocks, acceleration 15g, impulse duration from 10 to 15 msec, frequency 70 to 100 shocks per minute. Quantity shocks: 2000.

- One shock, acceleration 20g, impulse duration from 10 to 15 msec, frequency up to 30 shocks per minute. Quantity shocks: 10.

 
 
Battery type Voltage Nominal capacity C20 at 25°C Dimensions Lmax/B/H, mm Weight w/ electrolyte, kg

MBL 12 ST 86 PK

24 V

86

586/243/240

67



Operational temperature: From -50°C to 70°C
Reserve capacity: 145 min

Cranking current: 400 A

  • requirements at 25°C: 210 sec. to Uend = 18 V
  • requirements at -30°C: 50 sec. to Uend = 12 V


Life duration:

  • Motto hours: 1 000
  • Vehicle race: 50 000 km
  • Service life: 3 years
  • Storage (dry charged): 3 years
 
- Longtime shocks, acceleration 15g, impulse duration from 10 to 15 msec, frequency 70 to 100 shocks per minute. Quantity shocks: 2000.


- One shock, acceleration 20g, impulse duration from 10 to 15 msec, frequency up to 30 shocks per minute. Quantity shocks: 10.